LI-190R
Quantum Sensor
The LI-190R measures Photosynthetically Active Radiation (PAR, in µmol of photons m-2 s-1). It provides accurate measurements—in the open, in greenhouses, under plant canopies, or in growth chambers—for most broad-spectrum light sources, including natural sunlight, artificial, or mixed sources.
Plants use light in the wavelength range from about 400 to 700 nm to drive photosynthesis. The efficiency with which plants use light varies somewhat across this range, but McCree1 showed that measuring PAR provided a consistent way to predict plant photosynthetic response regardless of the spectrum of the light source.
Cosine correction is accurate even when the light source is not directly overhead
Sensor heads are detachable and interchangeable for simplified installation, removal, and recalibration
Why choose the LI-190R?
Newly designed optical filter tailors the spectral response to an unprecedented performance standard
Weather resistant and durable in high-temperature, high-humidity, long-term deployments
How does it work?
The LI‑190R uses a high-quality silicon photodiode and glass optical filter to create uniform sensitivity to light between 400 nm to 700 nm, which closely corresponds to light used by most plants. A newly designed optical filter tailors the spectral response to an unprecedented performance standard. Furthermore, the new filter is unaffected by environmental factors such as heat or humidity. The filter blocks light with wavelengths beyond 700 nm, which is critical for measurements under vegetation where the ratio of infrared to visible light may be high.
The sensor features excellent cosine response, which ensures accurate measurements under diffuse light and when sunlight originates from a low solar angle. This, in combination with high resolution at low light levels, makes the LI-190R useful for determining the light compensation point in plants.
Normalized response in photon units LI-190R Quantum Light Sensor
The figure above shows the LI-190R response and the ideal quantum response in photon units
Response in energy unitsLI-190R Quantum Light Sensor
The figure above shows the LI-190R response and the ideal quantum response in energy units
LI-190R Specifications
Sensitivity: Typically 5 μA to 10 μA per 1,000 μmol s-1 m-2
Linearity: Maximum deviation of 1% up to 10,000 μmol s-1 m-2
Response Time: Less than 1μs (2 m cable terminated into a 604 Ohm load)
Size: 2.36 cm diameter × 3.63 cm (0.93” × 1.43”)
Weight: 24 g head; 60 g base/cable (2 m) with screws
Cable Length: 2 m, 5 m, 15 m, 50 m (6.5’, 16.4’, 49.2’, 164’)